RV and marine banks: house versus starting

Two jobs, two batteries, and the compromise sitting in most RVs is the source of most disappointment. A starting battery wants thin plates and a burst of current; a house bank wants thick plates and slow, deep discharge.

Why "dual purpose" is a compromise

A dual-purpose battery is engineered to do both adequately rather than either well. If your rig has a single battery running the fridge, lights and inverter as well as cranking the engine, it is being asked to do a job it was not designed for — and the failure shows up as a fridge that stops overnight or a bank that lasts 18 months.

Sizing a house bank around daily loads

Add up a day's consumption in amp-hours at 12V: fridge 30-60Ah, lights 5-10Ah, inverter loads divided by ten (watts ÷ 10 = amps at 12V, roughly), charging devices 5-15Ah. Multiply the total by the days of autonomy you want, then divide by the depth of discharge you are willing to use.

Example: 80Ah per day, two days of autonomy, 50% DoD on lead-acid = 320Ah of lead-acid capacity, which is four 6V golf-cart style batteries in series-parallel or two large 12V units. The same duty on lithium at 80% DoD needs about 200Ah — smaller, lighter, and typically cheaper per usable amp-hour over life.

UseLead-acidLiFePO4
Weight for 200Ah usable~250 lb~90 lb
Charge acceptanceSlower, needs long absorptionFast, accepts most of what you give it
VentingFlooded needs ventingNo venting
Cold weatherWorks, capacity dropsNo charging below 0°C without heating
Cost per usable AhLower up frontLower over 5 years
Marine specifics: use marine-rated terminals and tinned cable, fuse every positive run at the battery, and never mix old and new batteries in one bank — the older cells drag the new ones down to their capacity.

Charging hardware decides satisfaction

A 30A converter/charger will take a long weekend to refill a 300Ah bank from half-empty. Lithium tolerates higher charge rates and will absorb them, which is why an upgraded charger often transforms a bank more than extra capacity does. Solar sizing follows the same logic: match the array to the bank, and favour MPPT controllers for anything above about 200W.